NM LYSE: Flow Cytometry Lysing Solution (CE/IVD)

NM LYSE: Flow Cytometry Lysing Solution (CE/IVD)
SKU
NORGAS-003-1-CE/IVD
Packaging Unit
100 ml (1000 Tests)
Manufacturer
Nordic-MUbio

Availability: loading...
Price is loading...
Background: For Wash- or No-Wash Lysing Procedures with Whole Blood or Marrow Samples NM-LYSE is a premixed, ready to use lysing solution fomulated for lysing erythrocytes following monoclonal antibody staining of whole blood. Treatment with this reagent simultaneously leads to lysis of red blood cells and fixation of white cells. Morphological scatter characteristics of leukocytes remain intact. NM-LYSE can be used with or without sample washing. NM-LYSE is suitable for the analysis of normal and malignant leukocyte populations derived from various human biological samples (blood, bone marrow and others) using flow cytometry. Results must be put within the context of other diagnostic tests as well as the clinical history of the patient by a certified professional before final interpretation. Flow cytometric analyses with monoclonal antibodies were so far restricted to leukocyte populations, which had been separated from erythrocytes before staining and/or analysis. Instead, whole blood staining methods allow for a rapid and accurate determination of cellular subpopulations in non-separated biological samples. This is not only time saving but reduces also the probability of an unintended loss of distinct cellular populations due to e.g. commonly used differential centrifugation procedures. With the NM-LYSE reagent flow cytometric analysis of whole blood has become as easy and accurate as the analysis of separated cell populations.Results must be put within the context of other diagnostic tests as well as the clinical history of the patient by a certified professional before final interpretation. Analyses performed with this antibody should be paralleled by positive and negative controls. If unexpected results are obtained, which cannot be attributed to differences in laboratory procedures, please contact us.

Specificity: NM-LYSE Reagent is designed for use with all commercially available flow cytometers. Alignment and compensation should be performed according to manufacturer´s instructions The quality of each NM-LYSE Lot is determined by lysing red blood cells of well defined blood samples from representative donors and subsequent comparison of forward and side scatter characteristics of obtained leukocytes.

References: 1. Bossuyt, X., Marti, G. E. & Fleisher, T. A. (1997) Cytometry 30, 124-33. 2. Fritsch, G., Printz, D., Stimpfl, M., Dworzak, M. N., Witt, V., Potschger, U. & Buchinger, P. (1997) Transfusion 37, 775-84. 3. Kormoczi, G. F., Wolfel, U. M., Rosenkranz, A. R., Horl, W. H., Oberbauer, R. & Zlabinger, G. J. (2001) J Immunol 167, 451-60. 4. Menendez, P., Redondo, O., Rodriguez, A., Lopez-Berges, M. C., Ercilla, G., Lopez, A., Duran, A., Almeida, J., Perez-Simon, J. A., San Miguel, J. F., Gratama, J. W. & Orfao, A. (1998) Cytometry 34, 264-71.

Caution: For professional users only. NM-LYSE contains fomaldehyde. Formaldehyde is toxic, allergenic and a suspected carcinogen. Avoid contact with eyes, skin and clothing. Proper handling procedures are recommended.
More Information
SKU NORGAS-003-1-CE/IVD
Manufacturer Nordic-MUbio
Manufacturer SKU GAS-003-1-CE/IVD
Package Unit 100 ml (1000 Tests)
Quantity Unit STK
Application Flow Cytometry
CE-IVD yes